Hartie si accesorii pentru industria textilelor
Director vanzari: 0722249451

osha hot work permit requirements 1926

Where relocation is impractical, combustibles shall be protected with flame proof covers, shielded with metal, guards, curtains, or wet down material to help prevent ignition of . Hot work areas shall not be less than 35 feet from combustible materials and combustible waste Torches shall be lighted by friction lighters or other approved devices, and not by matches or from hot work. When welding, cutting, or heating is performed on walls, floors, and ceilings, since direct penetration of sparks or heat transfer may introduce a fire hazard to an adjacent area, the same precautions shall be taken on the opposite side as are taken on the side on which the welding is being performed. All cylinders used shall meet the Department of Transportation requirements published in 49 CFR part 178, subpart C, Specification for Cylinders. Before entry operations begin, the controlling contractor must: Obtain the host employer's information about the permit space hazards and previous entry operations; and. 0000038376 00000 n %PDF-1.7 % F. FIRE SAFETY REQUIREMENTS (As per Section 2604 of FDNY Fire Code) Separation from combustibles. 2 A Project Permit authorizes an employer serving as a Project Administrator to conduct permit-required activity at specific location (s) 0000000016 00000 n )*@w>Hk'z&wjf6pM[OKo/!I:;jq:wicxLc;_Ka.\kS,0|;\KeO&)>W0upx!YeY[|I}Ug*uo/c[>/+ jMMM*YD2.Z=Vj %K2`.\Y+ 1926.758 - Systems-engineered metal buildings. This republication developed a single set of OSHA regulations for both labor and management forces within the construction industry. Exhausts from working spaces shall be discharged into the open air, clear of intake air sources; Replacement air shall be clean and respirable; and. 1926.1411 - Power line safetywhile traveling. A Hot Work . Adapters shall not be used to permit the interchange of hose. 0000021444 00000 n Cylinders shall be moved by tilting and rolling them on their bottom edges. Suitable fire extinguishing equipment shall be immediately available in the work area and shall be maintained in a state of readiness for instant use. 1926 Subpart O - Motor Vehicles, Mechanized Equipment, and Marine Operations. English 02/23/2023. A copy of the contractor's written Hot Work Permit Procedures shall be available for EH&S review. Drums, containers or hollow structures that have contained flammable or combustible substances shall either be filled with water or cleaned, and shall then be ventilated. 1926 Subpart G - Signs, Signals, and Barricades. When entrance covers are removed, the opening must be immediately guarded by a railing, temporary cover, or other temporary barrier that will prevent an accidental fall through the opening and that will protect each employee working in the space from foreign objects entering the space. Fuel gas and oxygen manifolds shall bear the name of the substance they contain in letters at least 1-inch high which shall be either painted on the manifold or on a sign permanently attached to it. No welding, cutting, or heating shall be done where the application of flammable paints, or the presence of other flammable compounds, or heavy dust concentrations creates a hazard. 1926.22 - Recording and reporting of injuries. Additional rules. 0000013465 00000 n Hose which has been subject to flashback, or which shows evidence of severe wear or damage, shall be tested to twice the normal pressure to which it is subject, but in no case less than 300 p.s.i. Highly flammable coatings shall be stripped from the area to be heated. 1926.12 - Reorganization Plan No. Fuel gas cylinders shall be placed with valve end up whenever they are in use. Definition. 2. When hot work must be performed in a location that is not free of fire hazards, all necessary precautions shall be taken to confine heat, sparks, and slag so that they cannot contact flammable or combustible material. 1926.703 - Requirements for cast-in-place Concrete. Nothing shall be placed on top of a cylinder or associated parts when the cylinder is in use. 67 0 obj <> endobj xref The hot work permit helps the permit authorizing individual, hot work operator, and fire watch recognize potential hazards. Get Form. Occupational Safety & Health Administration. Insulated connectors of equivalent capacity shall be used for connecting or splicing cable. 0000018793 00000 n 1926.1433 - Design, construction and testing. Ask how long hot work permits are valid. An employer may use the alternate procedures specified in paragraph (e)(2) of this section for entering a permit space only under the conditions set forth in paragraph (e)(1) of this section. 1926.1432 - Multiple-crane/derrick liftssupplemental requirements. 1926 Subpart L App C - List of National Consensus Standards. For additional details not covered in this subpart, applicable technical portions of American National Standards Institute, Z49.1-1967, Safety in Welding and Cutting, shall apply. 1926.30 - Shipbuilding and ship repairing. Oil shall not be used to lubricate caps; Shall be hoisted only while secured, as on a cradle or pallet, and shall not be hoisted by magnet, choker sling or cylinder caps; Shall be moved only by tilting or rolling on their bottom edges; Shall have valves closed when cylinders are empty, being moved or stored; Shall be secured upright except when hoisted or carried; Shall not be freed when frozen by prying the valves or caps with bars or by hitting the valve with a tool; Shall not be exposed to sparks, hot slag, or flame; Shall not be permitted to become part of electrical circuits or have electrodes struck against them to strike arcs; Shall not be used as rollers or supports; Shall not have contents used for purposes not authorized by the supplier; Shall not be used if damaged or defective; Shall not have gases mixed within, except by gas suppliers; Shall be stored so that oxygen cylinders are separated from fuel gas cylinders and combustible materials by either a minimum distance of 20 feet (6.1 m) or a barrier having a fire-resistance rating of 30 minutes; and. 1926.251 - Rigging equipment for material handling. 1926 Subpart R App G - 1926.502 (b)-(e) Fall Protection Systems Criteria and Practices. Boxes used for the storage of gas hose shall be ventilated. hot work have been covered with a wet rag. 1926.1050 - Scope, application, and definitions applicable to this subpart. 1926.1204 - Permit-required confined space program. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965. 1926.60 App A - Substance Data Sheet, for 4-4'-METHYLENEDIANILINE, 1926.60 App B - Substance Technical Guidelines, MDA, 1926.60 App C - Medical Surveillance Guidelines for MDA, 1926.60 App D - Sampling and Analytical Methods for MDA Monitoring and Measurement Procedures. 0000052667 00000 n 0000009221 00000 n The employer shall instruct all employees involved in hot work operations as to potential fire hazards and the use of firefighting equipment. Bulk sulphur is excluded from this prohibition if suitable precautions are followed, the person in charge is knowledgeable and the person performing the work has been instructed in preventing and extinguishing sulphur fires. USA Distributor of MCM Equipment osha hot work permit requirements 1926 Structures or pipelines acting continuously as ground return circuits shall have joints bonded and maintained to ensure that no electrolysis or fire hazard exists. 1926.851 - Stairs, passageways, and ladders. Before hot work is commenced on surfaces covered by a preservative coating of unknown flammability, a test shall be made by a designated person to determine the coating's flammability. 1926.441 - Batteries and battery charging. Empty containers shall be removed from the hot work area. 0000001616 00000 n Hot work in confined spaces. When cylinders are transported by powered vehicles, they shall be secured in a vertical position. This type of work can include welding, flame cutting, grinding, soldering, brazing and other activities that have the potential to cause fires or explosions. INTRODUCTION . They shall not be hoisted or transported by means of magnets or choker slings. Employees performing hot work in confined or enclosed spaces involving beryllium-containing base or filler metals shall be protected by local exhaust ventilation and wear supplied air respirators or self-contained breathing apparatus, in accordance with the requirements of 1910.134. hot work hazards and control measures pdf. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. 1926.958 - Materials handling and storage. Those measures can include, but are not limited to, the lockout or tagging of equipment and procedures for purging, inerting, ventilating, and flushing permit spaces. Electrodes shall not be struck against a cylinder to strike an arc. Use of fuel gas. Arc welding and cutting machine frames shall be grounded, either through a third wire in the cable containing the circuit conductor or through a separate wire at the source of the current. 1926.1429 - Qualifications of maintenance & repair employees. Any precautions that the host employer or any previous controlling contractor or entry employer implemented for the protection of employees in the permit space. 4. sb`aY Ground return cables shall have current-carrying capacity equal to or exceeding the total maximum output capacities of the welding or cutting units served. 0000016958 00000 n 1926.1102 - Coal tar pitch volatiles; interpretation of term. 1926.964 - Overhead lines and live-line barehand work. Ensure that all hot work requests have "Hot Permit Required" selected as the purpose. 0000023710 00000 n Use professional pre-built templates to fill in and sign documents online faster. H\0vFBHdGa} NicCyri]]malq~6!{9Ui^vvr]||f=mq{w|6>MiL*Wo0?^t_2W4Mmc.>}Sd>W6fN. 1926.700 - Scope, application, and definitions applicable to this subpart. Hose subjected to flashback or showing evidence of severe wear or damage shall be tested to twice the normal working pressure but not less than 200 p.s.i. Confined spaces and permit spaces. 0000002304 00000 n Attendant means an individual stationed outside one or more permit spaces who assesses the status of authorized . 0000046103 00000 n Includes how employers must control respiratory hazards in the space; testing the internal atmosphere; and what to document for each entry. 0000031614 00000 n Oxygen and fuel gas pressure regulators, including their related gauges, shall be in proper working order while in use. 0000041672 00000 n Manifold hose connections, including both ends of the supply hose that lead to the manifold, shall be such that the hose cannot be interchanged between fuel gas and oxygen manifolds and supply header connections. Note to paragraph (i). %\9 Standard for Fire Prevention During Welding, Cutting, and Other Hot Work This standard presents provisions to prevent injury, loss of life, and loss of property from fire or explosion as a result of hot work projects such as welding, heat treating, grinding, and similar applications producing or using sparks, flames, or heat. Assuming a hot work permit is required, it must be issued by a "Permit Authorizing Individual (PAI)." It is the responsibility of the department employing and supervising Oxygen shall not be directed at oily surfaces, greasy clothes, or within a fuel oil or other storage tank or vessel. The entry employer must then reevaluate the space and reclassify it as a permit space as appropriate in accordance with all other applicable provisions of this standard. [12] The U.S. Coast Guard, at 33 CFR 126.15(c), requires prior permission of the Captain of the Port if welding or other hot work is to be carried out at a facility where dangerous cargoes as defined by 33 CFR 126.07 are located or being handled. 0000015110 00000 n 1926.606 - Definitions applicable to this subpart. 1926.153 - Liquefied petroleum gas (LP-Gas). Pressure-reducing regulators shall be attached to cylinder valves when cylinders are supplying torches or devices equipped with shut-off valves; Cylinder valves shall be closed and gas released from the regulator or manifold before regulators are removed; Leaking fuel gas cylinder valves shall be closed and the gland nut tightened. 1926.350 Gas Welding and Cutting 1926.350 (a) Transporting, Moving, and Storing Compressed Gas Cylinders 1926.350 (a) (1) Valve protection caps shall be in place and secured. Before heat is applied to a drum, container or hollow structure, an opening to release built-up pressure during heat application shall be provided. 0000020449 00000 n 1917.152 - Welding, cutting and heating (hot work)[12] (See also 1917.2, definition of Hazardous cargo, materials, substance, or atmosphere). Welding, cutting and heating (hot work)[12] (See also 1917.2, definition of Hazardous cargo, materials, substance, or atmosphere). Hit the arrow with the inscription Next to move from field to field. Hose connections shall be clamped or securely fastened to withstand twice the normal working pressure but not less than 300 p.s.i. When a special wrench is required, it shall be left in position on the stem of the valve while the cylinder is in use so that the fuel gas flow can be shut off quickly in case of an emergency. 1926.902 - Surface transportation of explosives.

Among Elms And Maples Quizlet, Loveland City Manager, Articles O